Files
anvil/templates/basic/upload.bat
Eric Ratliff 60ba7c7bed Better
2026-02-18 20:15:46 -06:00

164 lines
5.1 KiB
Batchfile

@echo off
setlocal enabledelayedexpansion
:: upload.bat -- Compile and upload the sketch to the board
::
:: Reads all settings from .anvil.toml. No Anvil binary required.
::
:: Usage:
:: upload.bat Auto-detect port, compile + upload
:: upload.bat -p COM3 Specify port
:: upload.bat --monitor Open serial monitor after upload
:: upload.bat --clean Clean build cache first
:: upload.bat --verbose Full compiler + avrdude output
set "SCRIPT_DIR=%~dp0"
set "CONFIG=%SCRIPT_DIR%.anvil.toml"
set "LOCAL_CONFIG=%SCRIPT_DIR%.anvil.local"
if not exist "%CONFIG%" (
echo FAIL: No .anvil.toml found in %SCRIPT_DIR%
exit /b 1
)
:: -- Parse .anvil.toml ----------------------------------------------------
:: Read file directly, skip comments and section headers
for /f "usebackq tokens=1,* delims==" %%a in ("%CONFIG%") do (
set "_K=%%a"
if not "!_K:~0,1!"=="#" if not "!_K:~0,1!"=="[" (
set "_K=!_K: =!"
set "_V=%%b"
if defined _V (
set "_V=!_V: =!"
set "_V=!_V:"=!"
)
if "!_K!"=="name" set "SKETCH_NAME=!_V!"
if "!_K!"=="fqbn" set "FQBN=!_V!"
if "!_K!"=="warnings" set "WARNINGS=!_V!"
if "!_K!"=="baud" set "BAUD=!_V!"
)
)
:: -- Parse .anvil.local (machine-specific, not in git) --------------------
set "LOCAL_PORT="
if exist "%LOCAL_CONFIG%" (
for /f "usebackq tokens=1,* delims==" %%a in ("%LOCAL_CONFIG%") do (
set "_K=%%a"
if not "!_K:~0,1!"=="#" (
set "_K=!_K: =!"
set "_V=%%b"
if defined _V (
set "_V=!_V: =!"
set "_V=!_V:"=!"
)
if "!_K!"=="port" set "LOCAL_PORT=!_V!"
)
)
)
if "%SKETCH_NAME%"=="" (
echo FAIL: Could not read project name from .anvil.toml
exit /b 1
)
if "%BAUD%"=="" set "BAUD=115200"
set "SKETCH_DIR=%SCRIPT_DIR%%SKETCH_NAME%"
set "BUILD_DIR=%SCRIPT_DIR%.build"
:: -- Parse arguments ------------------------------------------------------
set "PORT="
set "DO_MONITOR=0"
set "DO_CLEAN=0"
set "VERBOSE="
:parse_args
if "%~1"=="" goto done_args
if "%~1"=="-p" set "PORT=%~2" & shift & shift & goto parse_args
if "%~1"=="--port" set "PORT=%~2" & shift & shift & goto parse_args
if "%~1"=="--monitor" set "DO_MONITOR=1" & shift & goto parse_args
if "%~1"=="--clean" set "DO_CLEAN=1" & shift & goto parse_args
if "%~1"=="--verbose" set "VERBOSE=--verbose" & shift & goto parse_args
if "%~1"=="--help" goto show_help
if "%~1"=="-h" goto show_help
echo FAIL: Unknown option: %~1
exit /b 1
:show_help
echo Usage: upload.bat [-p PORT] [--monitor] [--clean] [--verbose]
echo Compiles and uploads the sketch. Settings from .anvil.toml.
exit /b 0
:done_args
:: -- Preflight ------------------------------------------------------------
where arduino-cli >nul 2>nul
if errorlevel 1 (
echo FAIL: arduino-cli not found in PATH.
exit /b 1
)
:: -- Resolve port ---------------------------------------------------------
:: Priority: -p flag > .anvil.local > auto-detect
if "%PORT%"=="" (
if not "%LOCAL_PORT%"=="" (
set "PORT=!LOCAL_PORT!"
echo info Using port !PORT! ^(from .anvil.local^)
) else (
:: Use PowerShell helper for reliable JSON-based detection
for /f "delims=" %%p in ('powershell -NoProfile -ExecutionPolicy Bypass -File "%SCRIPT_DIR%_detect_port.ps1"') do (
if "!PORT!"=="" set "PORT=%%p"
)
if "!PORT!"=="" (
echo FAIL: No serial port detected. Is the board plugged in?
echo Specify manually: upload.bat -p COM3
echo Or save a default: anvil devices --set COM3
exit /b 1
)
echo warn Auto-detected port: !PORT! ^(use -p to override, or: anvil devices --set^)
)
)
:: -- Clean ----------------------------------------------------------------
if "%DO_CLEAN%"=="1" (
if exist "%BUILD_DIR%" rmdir /s /q "%BUILD_DIR%"
)
:: -- Build include flags --------------------------------------------------
set "BUILD_FLAGS="
for %%d in (lib\hal lib\app) do (
if exist "%SCRIPT_DIR%%%d" (
set "BUILD_FLAGS=!BUILD_FLAGS! -I%SCRIPT_DIR%%%d"
)
)
set "BUILD_FLAGS=!BUILD_FLAGS! -Werror"
:: -- Compile --------------------------------------------------------------
echo Compiling %SKETCH_NAME%...
if not exist "%BUILD_DIR%" mkdir "%BUILD_DIR%"
arduino-cli compile --fqbn %FQBN% --build-path "%BUILD_DIR%" --warnings %WARNINGS% --build-property "build.extra_flags=%BUILD_FLAGS%" %VERBOSE% "%SKETCH_DIR%"
if errorlevel 1 (
echo FAIL: Compilation failed.
exit /b 1
)
echo ok Compile succeeded.
:: -- Upload ---------------------------------------------------------------
echo.
echo Uploading to %PORT%...
arduino-cli upload --fqbn %FQBN% --port %PORT% --input-dir "%BUILD_DIR%" %VERBOSE%
if errorlevel 1 (
echo FAIL: Upload failed.
exit /b 1
)
echo ok Upload complete!
:: -- Monitor --------------------------------------------------------------
if "%DO_MONITOR%"=="1" (
echo.
echo Opening serial monitor on %PORT% at %BAUD% baud...
echo Press Ctrl+C to exit.
echo.
arduino-cli monitor -p %PORT% -c "baudrate=%BAUD%"
)