@echo off setlocal enabledelayedexpansion :: monitor.bat -- Open the serial monitor :: :: Reads baud rate from .anvil.toml. No Anvil binary required. :: :: Usage: :: monitor.bat Open monitor (auto-detect port) :: monitor.bat -p COM3 Specify port :: monitor.bat -b 9600 Override baud rate :: monitor.bat --board mega Use baud from a named board set "SCRIPT_DIR=%~dp0" set "SCRIPT_DIR=%SCRIPT_DIR:~0,-1%" set "CONFIG=%SCRIPT_DIR%\.anvil.toml" set "LOCAL_CONFIG=%SCRIPT_DIR%\.anvil.local" if not exist "%CONFIG%" ( echo FAIL: No .anvil.toml found in %SCRIPT_DIR% exit /b 1 ) :: -- Parse .anvil.toml (flat keys) ---------------------------------------- for /f "usebackq tokens=1,* delims==" %%a in ("%CONFIG%") do ( set "_K=%%a" if not "!_K:~0,1!"=="#" if not "!_K:~0,1!"=="[" ( set "_K=!_K: =!" set "_V=%%b" if defined _V ( set "_V=!_V: =!" set "_V=!_V:"=!" ) if "!_K!"=="default" set "DEFAULT_BOARD=!_V!" if "!_K!"=="baud" set "BAUD=!_V!" ) ) :: -- Parse .anvil.local --------------------------------------------------- set "LOCAL_PORT=" set "LOCAL_VID_PID=" if exist "%LOCAL_CONFIG%" ( for /f "usebackq tokens=1,* delims==" %%a in ("%LOCAL_CONFIG%") do ( set "_K=%%a" if not "!_K:~0,1!"=="#" ( set "_K=!_K: =!" set "_V=%%b" if defined _V ( set "_V=!_V: =!" set "_V=!_V:"=!" ) if "!_K!"=="port" set "LOCAL_PORT=!_V!" if "!_K!"=="vid_pid" set "LOCAL_VID_PID=!_V!" ) ) ) if "%BAUD%"=="" set "BAUD=115200" :: -- Parse arguments ------------------------------------------------------ set "PORT=" set "BOARD_NAME=" :parse_args if "%~1"=="" goto done_args if "%~1"=="-p" set "PORT=%~2" & shift & shift & goto parse_args if "%~1"=="--port" set "PORT=%~2" & shift & shift & goto parse_args if "%~1"=="-b" set "BAUD=%~2" & shift & shift & goto parse_args if "%~1"=="--baud" set "BAUD=%~2" & shift & shift & goto parse_args if "%~1"=="--board" set "BOARD_NAME=%~2" & shift & shift & goto parse_args if "%~1"=="--help" goto show_help if "%~1"=="-h" goto show_help echo FAIL: Unknown option: %~1 exit /b 1 :show_help echo Usage: monitor.bat [-p PORT] [-b BAUD] [--board NAME] echo Opens serial monitor. Baud rate from .anvil.toml. echo --board NAME selects a board from [boards.NAME]. exit /b 0 :done_args :: -- Resolve board -------------------------------------------------------- if "%BOARD_NAME%"=="" set "BOARD_NAME=%DEFAULT_BOARD%" if "%BOARD_NAME%"=="" ( echo FAIL: No default board set in .anvil.toml. echo. echo Add a default to the [build] section of .anvil.toml: echo default = "uno" echo. echo And make sure a matching [boards.uno] section exists: echo [boards.uno] echo fqbn = "arduino:avr:uno" echo. echo Or with Anvil: anvil board --default uno echo List boards: anvil board --listall echo arduino-cli board listall exit /b 1 ) set "BOARD_SECTION=[boards.%BOARD_NAME%]" set "IN_SECTION=0" set "BOARD_BAUD=" for /f "usebackq tokens=*" %%L in ("%CONFIG%") do ( set "_LINE=%%L" if "!_LINE!"=="!BOARD_SECTION!" ( set "IN_SECTION=1" ) else if "!IN_SECTION!"=="1" ( if "!_LINE:~0,1!"=="[" ( set "IN_SECTION=0" ) else if not "!_LINE:~0,1!"=="#" ( for /f "tokens=1,* delims==" %%a in ("!_LINE!") do ( set "_BK=%%a" set "_BK=!_BK: =!" set "_BV=%%b" if defined _BV ( set "_BV=!_BV: =!" set "_BV=!_BV:"=!" ) if "!_BK!"=="baud" set "BOARD_BAUD=!_BV!" ) ) ) ) if not "!BOARD_BAUD!"=="" set "BAUD=!BOARD_BAUD!" if not "%BOARD_NAME%"=="%DEFAULT_BOARD%" ( echo ok Using board: %BOARD_NAME% -- baud: !BAUD! ) :: -- Preflight ------------------------------------------------------------ where arduino-cli >nul 2>nul if errorlevel 1 ( echo FAIL: arduino-cli not found in PATH. exit /b 1 ) :: -- Resolve port --------------------------------------------------------- :: Priority: -p flag > VID:PID resolve > saved port > auto-detect if "%PORT%"=="" ( for /f "delims=" %%p in ('powershell -NoProfile -ExecutionPolicy Bypass -File "%SCRIPT_DIR%\_detect_port.ps1" -VidPid "%LOCAL_VID_PID%" -SavedPort "%LOCAL_PORT%"') do ( if "!PORT!"=="" set "PORT=%%p" ) if "!PORT!"=="" ( echo FAIL: No serial port detected. Specify with: monitor.bat -p COM3 echo Or save a default: anvil devices --set exit /b 1 ) if not "%LOCAL_VID_PID%"=="" ( if not "!PORT!"=="%LOCAL_PORT%" ( echo info Device %LOCAL_VID_PID% found on !PORT! ^(moved from %LOCAL_PORT%^) ) else ( echo info Using port !PORT! ^(from .anvil.local^) ) ) else if not "%LOCAL_PORT%"=="" ( echo info Using port !PORT! ^(from .anvil.local^) ) else ( echo warn Auto-detected port: !PORT! ^(use -p to override, or: anvil devices --set^) ) ) :: -- Monitor -------------------------------------------------------------- echo Opening serial monitor on %PORT% at %BAUD% baud... echo Press Ctrl+C to exit. echo. arduino-cli monitor -p %PORT% -c "baudrate=%BAUD%"