Refactor CLI, add refresh command, fix port detection, add device tracking
- Remove build/upload/monitor subcommands (projects are self-contained) - Remove ctrlc dependency (only used by removed monitor watch mode) - Update next-steps messaging to reference project scripts directly - Add 'anvil refresh [DIR] [--force]' to update project scripts to latest templates without touching user code - Fix Windows port detection: replace fragile findstr/batch TOML parsing with proper comment-skipping logic; add _detect_port.ps1 helper for reliable JSON-based port detection via PowerShell - Add .anvil.local for machine-specific config (gitignored) - 'anvil devices --set [PORT] [-d DIR]' saves port + VID:PID - 'anvil devices --get [-d DIR]' shows saved port status - VID:PID tracks USB devices across COM port reassignment - Port resolution: -p flag > VID:PID > saved port > auto-detect - Uppercase normalization for Windows COM port names - Update all .bat/.sh templates to read from .anvil.local - Remove port entries from .anvil.toml (no machine-specific config in git) - Add .anvil.local to .gitignore template - Expand 'anvil devices' output with VID:PID, serial number, and usage instructions
This commit is contained in:
169
templates/basic/upload.bat
Normal file
169
templates/basic/upload.bat
Normal file
@@ -0,0 +1,169 @@
|
||||
@echo off
|
||||
setlocal enabledelayedexpansion
|
||||
|
||||
:: upload.bat -- Compile and upload the sketch to the board
|
||||
::
|
||||
:: Reads all settings from .anvil.toml. No Anvil binary required.
|
||||
::
|
||||
:: Usage:
|
||||
:: upload.bat Auto-detect port, compile + upload
|
||||
:: upload.bat -p COM3 Specify port
|
||||
:: upload.bat --monitor Open serial monitor after upload
|
||||
:: upload.bat --clean Clean build cache first
|
||||
:: upload.bat --verbose Full compiler + avrdude output
|
||||
|
||||
set "SCRIPT_DIR=%~dp0"
|
||||
set "CONFIG=%SCRIPT_DIR%.anvil.toml"
|
||||
set "LOCAL_CONFIG=%SCRIPT_DIR%.anvil.local"
|
||||
|
||||
if not exist "%CONFIG%" (
|
||||
echo FAIL: No .anvil.toml found in %SCRIPT_DIR%
|
||||
exit /b 1
|
||||
)
|
||||
|
||||
:: -- Parse .anvil.toml ----------------------------------------------------
|
||||
for /f "usebackq tokens=1,* delims==" %%a in ("%CONFIG%") do (
|
||||
set "_K=%%a"
|
||||
if not "!_K:~0,1!"=="#" if not "!_K:~0,1!"=="[" (
|
||||
set "_K=!_K: =!"
|
||||
set "_V=%%b"
|
||||
if defined _V (
|
||||
set "_V=!_V: =!"
|
||||
set "_V=!_V:"=!"
|
||||
)
|
||||
if "!_K!"=="name" set "SKETCH_NAME=!_V!"
|
||||
if "!_K!"=="fqbn" set "FQBN=!_V!"
|
||||
if "!_K!"=="warnings" set "WARNINGS=!_V!"
|
||||
if "!_K!"=="baud" set "BAUD=!_V!"
|
||||
)
|
||||
)
|
||||
|
||||
:: -- Parse .anvil.local (machine-specific, not in git) --------------------
|
||||
set "LOCAL_PORT="
|
||||
set "LOCAL_VID_PID="
|
||||
if exist "%LOCAL_CONFIG%" (
|
||||
for /f "usebackq tokens=1,* delims==" %%a in ("%LOCAL_CONFIG%") do (
|
||||
set "_K=%%a"
|
||||
if not "!_K:~0,1!"=="#" (
|
||||
set "_K=!_K: =!"
|
||||
set "_V=%%b"
|
||||
if defined _V (
|
||||
set "_V=!_V: =!"
|
||||
set "_V=!_V:"=!"
|
||||
)
|
||||
if "!_K!"=="port" set "LOCAL_PORT=!_V!"
|
||||
if "!_K!"=="vid_pid" set "LOCAL_VID_PID=!_V!"
|
||||
)
|
||||
)
|
||||
)
|
||||
|
||||
if "%SKETCH_NAME%"=="" (
|
||||
echo FAIL: Could not read project name from .anvil.toml
|
||||
exit /b 1
|
||||
)
|
||||
if "%BAUD%"=="" set "BAUD=115200"
|
||||
|
||||
set "SKETCH_DIR=%SCRIPT_DIR%%SKETCH_NAME%"
|
||||
set "BUILD_DIR=%SCRIPT_DIR%.build"
|
||||
|
||||
:: -- Parse arguments ------------------------------------------------------
|
||||
set "PORT="
|
||||
set "DO_MONITOR=0"
|
||||
set "DO_CLEAN=0"
|
||||
set "VERBOSE="
|
||||
|
||||
:parse_args
|
||||
if "%~1"=="" goto done_args
|
||||
if "%~1"=="-p" set "PORT=%~2" & shift & shift & goto parse_args
|
||||
if "%~1"=="--port" set "PORT=%~2" & shift & shift & goto parse_args
|
||||
if "%~1"=="--monitor" set "DO_MONITOR=1" & shift & goto parse_args
|
||||
if "%~1"=="--clean" set "DO_CLEAN=1" & shift & goto parse_args
|
||||
if "%~1"=="--verbose" set "VERBOSE=--verbose" & shift & goto parse_args
|
||||
if "%~1"=="--help" goto show_help
|
||||
if "%~1"=="-h" goto show_help
|
||||
echo FAIL: Unknown option: %~1
|
||||
exit /b 1
|
||||
|
||||
:show_help
|
||||
echo Usage: upload.bat [-p PORT] [--monitor] [--clean] [--verbose]
|
||||
echo Compiles and uploads the sketch. Settings from .anvil.toml.
|
||||
exit /b 0
|
||||
|
||||
:done_args
|
||||
|
||||
:: -- Preflight ------------------------------------------------------------
|
||||
where arduino-cli >nul 2>nul
|
||||
if errorlevel 1 (
|
||||
echo FAIL: arduino-cli not found in PATH.
|
||||
exit /b 1
|
||||
)
|
||||
|
||||
:: -- Resolve port ---------------------------------------------------------
|
||||
:: Priority: -p flag > VID:PID resolve > saved port > auto-detect
|
||||
if "%PORT%"=="" (
|
||||
for /f "delims=" %%p in ('powershell -NoProfile -ExecutionPolicy Bypass -File "%SCRIPT_DIR%_detect_port.ps1" -VidPid "%LOCAL_VID_PID%" -SavedPort "%LOCAL_PORT%"') do (
|
||||
if "!PORT!"=="" set "PORT=%%p"
|
||||
)
|
||||
if "!PORT!"=="" (
|
||||
echo FAIL: No serial port detected. Is the board plugged in?
|
||||
echo Specify manually: upload.bat -p COM3
|
||||
echo Or save a default: anvil devices --set
|
||||
exit /b 1
|
||||
)
|
||||
if not "%LOCAL_VID_PID%"=="" (
|
||||
if not "!PORT!"=="%LOCAL_PORT%" (
|
||||
echo info Device %LOCAL_VID_PID% found on !PORT! ^(moved from %LOCAL_PORT%^)
|
||||
) else (
|
||||
echo info Using port !PORT! ^(from .anvil.local^)
|
||||
)
|
||||
) else if not "%LOCAL_PORT%"=="" (
|
||||
echo info Using port !PORT! ^(from .anvil.local^)
|
||||
) else (
|
||||
echo warn Auto-detected port: !PORT! ^(use -p to override, or: anvil devices --set^)
|
||||
)
|
||||
)
|
||||
|
||||
:: -- Clean ----------------------------------------------------------------
|
||||
if "%DO_CLEAN%"=="1" (
|
||||
if exist "%BUILD_DIR%" rmdir /s /q "%BUILD_DIR%"
|
||||
)
|
||||
|
||||
:: -- Build include flags --------------------------------------------------
|
||||
set "BUILD_FLAGS="
|
||||
for %%d in (lib\hal lib\app) do (
|
||||
if exist "%SCRIPT_DIR%%%d" (
|
||||
set "BUILD_FLAGS=!BUILD_FLAGS! -I%SCRIPT_DIR%%%d"
|
||||
)
|
||||
)
|
||||
set "BUILD_FLAGS=!BUILD_FLAGS! -Werror"
|
||||
|
||||
:: -- Compile --------------------------------------------------------------
|
||||
echo Compiling %SKETCH_NAME%...
|
||||
if not exist "%BUILD_DIR%" mkdir "%BUILD_DIR%"
|
||||
|
||||
arduino-cli compile --fqbn %FQBN% --build-path "%BUILD_DIR%" --warnings %WARNINGS% --build-property "build.extra_flags=%BUILD_FLAGS%" %VERBOSE% "%SKETCH_DIR%"
|
||||
if errorlevel 1 (
|
||||
echo FAIL: Compilation failed.
|
||||
exit /b 1
|
||||
)
|
||||
echo ok Compile succeeded.
|
||||
|
||||
:: -- Upload ---------------------------------------------------------------
|
||||
echo.
|
||||
echo Uploading to %PORT%...
|
||||
|
||||
arduino-cli upload --fqbn %FQBN% --port %PORT% --input-dir "%BUILD_DIR%" %VERBOSE%
|
||||
if errorlevel 1 (
|
||||
echo FAIL: Upload failed.
|
||||
exit /b 1
|
||||
)
|
||||
echo ok Upload complete!
|
||||
|
||||
:: -- Monitor --------------------------------------------------------------
|
||||
if "%DO_MONITOR%"=="1" (
|
||||
echo.
|
||||
echo Opening serial monitor on %PORT% at %BAUD% baud...
|
||||
echo Press Ctrl+C to exit.
|
||||
echo.
|
||||
arduino-cli monitor -p %PORT% -c "baudrate=%BAUD%"
|
||||
)
|
||||
Reference in New Issue
Block a user